Chapter 5 Setup
124
Item
Setting
*1
Details
Case Weight - Registers the weight of the 600 ml ink cartridge case which is
installed with the ink IC chip. "Correct the ink cartridge
weight"(P. 126)
Cartridge Weight - Registers the weight of the 600 ml ink cartridge where the ink
pack is set. "Correct the ink cartridge weight"(P. 126)
*1. The default settings are shown underlined.
*2. Displayed only when 600 ml ink cartridges are used.
Registering and Correcting a 600 ml Ink Cartridge
l
Required Items
Name Overview
600 ml ink cartridge
case
The 600 ml ink pack and the ink IC chip provided with the ink pack are placed in
the 600 ml ink cartridge case.
600 ml ink pack
Ink IC chip
Scale The weight of the 600 ml ink cartridge is registered to calculate the amount of
remaining ink. Use a scale capable of weighing in 1 g increments.
When using for the first time
Mounting the ink cartridge in the ink station slot automatically launches the weight registering function.
• If initial filling has not been performed, the weight registering function launches once initial filling
is completed.
1
Attach the ink IC chip to the 600 ml ink cartridge case.
2
Weigh the 600 ml ink cartridge case.
• Do not install the ink pack or ink IC chip at this stage.
• Write down the cartridge case weight on a label or convenient location on the case to
avoid forgetting it after weighing.
3
Place the ink pack inside the 600 ml ink cartridge case.
• "Replacing Ink"(P. 40)
4
Install the 600 ml ink cartridge in the ink supply unit.
• The case weight registration screen appears.
5
Enter the measured weight of the 600 ml ink cartridge case, then press the [ENTER] key.
• If "ERROR 614 Preservation Failure" appears, check the following:
(1) Check to confirm that the 600 ml ink cartridge has been pushed in fully.
(2) Check to confirm the ink IC chip has been inserted correctly.