– 4.56 –
4-4-17. TEMP CHECK
[Function]
Displays the temperature around the head.
[Operation]
1) Select the TEST.
Press the
ENTER
key.
2) Select the “TEMP CHECK” pressing the
FUNCTION
key.
Press the
ENTER
key
3) Displays the temerature around the head.
Select the head using the
or key to
display the temperature around each head.
Temperature around the head and the entered
value to change AD.
Ta1 to Ta6 : H1, H2, ......,H6
•Temperature of the nozzle and forward voltage
drop of diodes.
Tj1A, Tj1B to Tj6B : H1A, H2B, ......,H6B
4) Press the
key to exit from the
function.
FUNCTION
# TEST < ENT >
# TEST
TEMP CHECK < ent >
# TEMP CHECK
Ta 1 =
ο
# TEMP CHECK
Ta 2 =
ο
# TEMP CHECK
Ta 3 =
ο
# TEMP CHECK
Ta 4 =
ο
# TEMP CHECK
T j 1A =
ο
# TEMP CHECK
T j 1B =
ο