68
Procedures
1
Press the key for about one second.
The load display will show “FUNC”.
2
Press the key 9 times.
The load display will change as “FUNC”
“CCAL”“ACAL”“LCAL”“ZERO”
“SPAN”“TARE”“CHEK”“MONT”
“VCAL”.
3
Press the key.
The load display will show “ALOW”.
4
Press the key.
The load display will flash on and off showing
“ALOW”.
At the same time, the analog output equivalent
to the minimum value of analog output will be
obtained.
Adjust so the output will become the minimum
value with the right keys.
Minimum
value
Voltage output
(Standard)
Current output
(Optional)
0V 4mA
It can be increased continuously by the
continuity press of the key.
key Decrease the analog output
key Increase the analog output