97
F
ITTING THE COMMUNICATION SERVER
CHAPTER 4 INSTALLATION
Figure 4.6: Placing two communication servers above each other inside a 19” rack
Rack-mounting procedure
Materials required:
Rack-mounting kit
Screw set for wall/desktop installation
Screwdriver
To rack-mount a communication server proceed as follows:
1.
Pull off the screw covers on the left and right of the front panel.
2. Secure the mounting plates to the communication server using the M4 screws. Make sure the front
panel and the mounting plate are aligned.
3. Shut down the communication server (see Shut-down mode) and disconnect it from the power
supply.
CAUTION: Be sure to observe the Safety regulations.
4. Remove the housing cover.
5. Connect the earthing (see Connecting the earthing wire).
6. Fit the housing cover.