CHAPTER 6 OPERATION AND MAINTENANCE
Malfunction of the Mitel DECT radio unit
Malfunctions of Mitel DECT cordless phones
Table 6.17:Malfunction of the Mitel DECT radio unit
Error description Error cause / error handling
No radio connection in a coverage area. Check LED on radio unit:
LED is flashing red (short red phase):
Check power supply / line length of DSI
bus cable
LED is flashing red (long red phase):
Check DSI bus cable
Unplug DSI bus cable for one minute,
then reconnect
LED is flashing green (long green phase):
All B channels busy
Radio unit not activated. LED on radio unit is flashing red/green
(various patterns):
Radio unit in startup phase
LED on radio unit is flashing red (long red
phase):
Radio unit defective
If LED on radio unit not flashing:
Check trunk connections
Radio unit defective
LED of the radio units deactivated
throughout the system
Table 6.18:Malfunctions of Mitel DECT cordless phones (Sheet 1 of 2)
Error description Error cause / error handling
No display. Switch cordless phone on and test
Replace or charge battery
No radio link to radio unit; no aerial
symbol.
Check coverage area (within range of a radio unit).
Check radio units in this section
Cordless phone not registered with the system
Cordless phone registered
Impossible to dial. Keypad blocked (keylock)
Unlock keypad