215
O
PERATIONS SUPERVISION
CHAPTER 6 OPERATION AND MAINTENANCE
Incompatible PMS
application
The external hotel management
system (PMS application) is not
suitable for communicating with
the communication server.
PMS SW
version, PMS
interface
version, PMS
interface
driver version,
date, time
critical (negative,
with match)
Incorrect or no wiring
adapter (Mitel 415/430
and Mitel SMBC only)
There is no wiring adapter in the
wiring adapter slot or the wiring
adapter fitted is unsuitable.
Slot number,
date, time
Critical (without
match)
Insufficient bandwidth An user in an AIN is trying to set up
a connection and the bandwidth
currently available with the WAN
link is insufficient.
Link ID, WAN
link name,
available
bandwidth in
Kbit/s, date,
clock
Serious (without
match)
Internal event message
destination not
reachable
Local output blocked or not
available
Cause (0: Busy
/1: Not
available
/2:(not used),
2: Barred /3:
not defined),
date, time
Serious (negative,
with match)
Internal event message
destination reachable
Local output available once again Date, time Serious (positive,
with match)
Internal power supply
unit failed (Mitel 470
only)
The internal power supply unit of
the communication server has
failed. If the auxiliary power supply
unit has been used for redundant
operation, there are no short-term
limitations. If the auxiliary power
supply unit has been used to
increase the power supply, the
external power supply unit
overflow must be calculated.
Date, time Serious (negative,
with match)
Internal power supply
unit in service (Mitel
470 only)
The internal power supply unit of
the communication server is in
service.
Date, time Serious (positive,
with match)
Table 6.12:Event types, in alphabetical order (Continued) (Sheet 8 of 25)

Table of Contents