228
O
PERATIONS SUPERVISION
CHAPTER 6 OPERATION AND MAINTENANCE
System phone in
service again
A system phone on the DSI bus is
ready for operation again.
Card number,
port number,
user number,
date, time
critical (positive,
with match)
System phone out of
service
A system phone on the DSI bus is
defective or was disconnected.
Card number,
port number,
user number,
date, time
critical (negative,
with match)
Temperature within
normal range again
Following overheating, the
temperature inside the
communication server is back in the
normal operating range.
Card number,
temperature,
date, time
critical (positive,
with match)
Temporary activation
expires on
Reminder of the missing, definitive
activation licence following
connection set-up with the
communication server.
Expiration date
[DD.MM.YYYY],
date, time
Serious (without
match)
Terminal power supply:
Overload (Mitel 470
only)
Rated output slightly exceeded for >
4 s.
Date, time critical (negative,
with match)
Terminal power supply:
Shut-down (Mitel 470
only)
Rated output clearly exceeded for 4
s
Date, time critical (negative,
with match)
Terminal power supply:
Switching back on
(Mitel 470 only)
The power supply to the terminals
was switched back on after
deactivation due to overflow.
Date, time critical (positive,
with match)
Terminal power supply:
Within normal range
again (Mitel 470 only)
The power supply to the terminals
is back in the normal rated output
range following a slight, preceding
overflow.
Date, time critical (positive,
with match)
Test event message The configuration of message
destinations can be tested with this
event message.
Date, time Serious (without
match)
The communication
server has been
restarted
The communication server was
restarted manually or automatically
due to an error.
Date, time Critical (without
match)
Table 6.12:Event types, in alphabetical order (Continued) (Sheet 21 of 25)