232
O
PERATIONS SUPERVISION
CHAPTER 6 OPERATION AND MAINTENANCE
Too few VoIP channels An user is trying to set up a
connection that requires one or
more VoIP channels which are
currently not available.
Available VoIP
channels on
this node,
date, time
Normal (without
match)
Too many errors with
the same ID
An unusual amount of errors (more
than 50 per hour) with the same
error ID have occurred.
Error ID, date,
time
Normal (without
match)
Too many event
messages
Number of message types exceeds
limit entered in the table on:
• "Synch. "Synch.loss on BRI/PRI"
• "Outgoing Call Rejected"
• "No response from network"
Date, time Normal (without
match)
Too much user data System capacity exceeded Date, time Critical (without
match)
Total synchronization
loss
Network synchronisation has failed
on all BRI/PRI interfaces
Date, time Serious (negative,
with match)
Trial licence expired The duration for which a trial
licence can be used for a specific
feature has expired and there is no
valid licence.
Licence ID,
date, time
Serious (without
match)
USER EVENT MESSAGE With *77[nnnn] from a terminal nnnn
[0000...99999]
, user number,
date, time
Serious (without
match)
User memory usage
below the critical range
again
The memory usage in the file
system for a specific user has again
fallen below a defined (Serious
severity level) or critical (Critical
severity level) value.
User number,
memory usage
in %, date,
time
Serious / Critical
(positive, with
match)
User memory usage
over the critical range
The memory usage in the file
system for a specific user has
exceeded a defined (Serious
severity level) or critical (Critical
severity level) value.
User number,
memory usage
in %, date,
time
Serious / Critical
(negative, with
match)
Wake-up call failed The room wake-up call was not
answered
Room No.,
date, time
Normal (negative,
with match)
Wake-up order
confirmed
The room wake-up call has now
been answered
Room No.,
date, time
Normal (positive,
with match)
Table 6.12:Event types, in alphabetical order (Continued) (Sheet 25 of 25)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitel SMB Controller and is the answer not in the manual?

Mitel SMB Controller Specifications

General IconGeneral
BrandMitel
ModelSMB Controller
CategoryController
LanguageEnglish

Related product manuals