256
T
ECHNICAL DATA
CHAPTER 7 ANNEX
Ambient temperature 5 °C to 45 °C
Relative air humidity 30 % to 80 %, non-condensating
Table 7.6:Electrical data
Mitel 415 Mitel 430
Class of protection 1
Input voltage 95 V…253 V, 48…62 Hz
Input current approx. 0.11 A...0.7 A approx. 0.11 A...1.0 A
Resistant to voltage breaks lt; 6ms
Power input with min.
configuration
approx. 15 W approx. 15 W
Power input with max.
configuration
approx. 50 W approx. 75 W
Undervoltage limit (system
reset, data backup)
lt; 90 V
Table 7.7:Heat dissipation
Mitel 415 Mitel 430
Maximally configured
system
approx. 37 W = 135 kJ/h approx. 50 W = 180 kJ/h
Table 7.8:Dimensions and weights
Mitel SMBC for wall
mounting
Mitel SMBC in rack
mounting
Height 65 mm 65 mm
Width 360 mm 483 mm
Depth 294mm 294mm
Weight (excl. mains cord,
interfaces cards, modules
and packaging)
2.4 kg 2.5 kg
Table 7.9:Electrical isolation of interfaces (Sheet 1 of 2)
Interface Mitel SMBC
Table 7.5:Ambient conditions (Continued) (Sheet 2 of 2)