5 - 106
Chapter 5 Data Used for Positioning Control
Setting value
Setting value buffer memory
address
Item
Value set with GX Works2 Value set with sequence program
Default
value
QD77MS2
QD77MS4
QD77MS16
2: 2 axes 2H
3: 3 axes 3H
Da.23 Number
of simultaneously
starting axes
QD77MS16
4: 4 axes
4H
Da.24
Simultaneously
starting axis No.1
QD77MS16
Da.25
Simultaneously
starting axis No.2
QD77MS16
Simultaneously starting axis
Da.26
Simultaneously
starting axis No.3
QD77MS16
0: Axis 1 selected
1: Axis 2 selected
2: Axis 3 selected
3: Axis 4 selected
4: Axis 5 selected
5: Axis 6 selected
6: Axis 7 selected
7: Axis 8 selected
8: Axis 9 selected
9: Axis 10 selected
A: Axis 11 selected
B: Axis 12 selected
C: Axis 13 selected
D: Axis 14 selected
E: Axis 15 selected
F: Axis 16 selected
0H
1H
2H
3H
4H
5H
6H
7H
8H
9H
AH
BH
CH
DH
EH
FH
Da.24Da.26 Da.25Da.23
b0b4b8b12b15
0000H
22101+400n
n: Axis No.-1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC-Q QD77MS and is the answer not in the manual?

Mitsubishi MELSEC-Q QD77MS Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC-Q QD77MS
CategoryControl Unit
LanguageEnglish

Related product manuals