5 - 161
Chapter 5 Data Used for Positioning Control
Storage buffer
memory address
Setting value
Default
value
QD77MS2
QD77MS4
QD77MS16
Set with a decimal.
Setting
v
alue
Positioning data No.
1 to 600
7000 to7004
9001
9002
9003
9004
K
: Positioning data No.
: Block start designation
: Machine OPR
: Fast-OPR
: Current value changing
: Simultaneous starting of multiple axes
0 1500+100n 4300+100n
Set with a decimal.
Setting
value
K
Positioning starting point No.
The QD77MS resets the value to "0" automatically when the continuous
operation is interrupted.
1 to 50
0 1501+100n 4301+100n
Set with a decimal.
K
1
Error reset request
Setting value
The QD77MS resets the value to "0" automatically after the axis error rese
t
is com
p
leted.
(
Indicates that the axis error reset is com
p
leted.
)
1: Axis error is reset.
0 1502+100n 4302+100n
Set with a decimal.
K
1
Restart command
Setting value
The QD77MS resets the value to "0" automatically after restart acceptance
is completed. (Indicates that the restart acceptance is completed.)
1: Restarts
0 1503+100n 4303+100n
n: Axis No.-1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC-Q QD77MS and is the answer not in the manual?

Mitsubishi MELSEC-Q QD77MS Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC-Q QD77MS
CategoryControl Unit
LanguageEnglish

Related product manuals