Chapter 5 Data Used for Positioning Control
Setting item Setting details
Cd.19
OPR request flag OFF
request
The sequence program can use this data item to forcibly turn the OPR request
flag from ON to OFF.
Fetch cycle: 14.2[ms]
POINT
This parameter is made valid when the increment system is valid.
Cd.20
Manual pulse generator 1
pulse input magnification
This data item determines the factor by which the number of pulses from the
manual pulse generator is magnified.
Value "0" : read as "1".
Value "10001 or more" or negative value : read as "10000".
Fetch cycle: Operation cycle (At manual pulse generator enabled)
Cd.21
Manual pulse generator
enable flag
This data item enables or disables operations using a manual pulse generator.
Fetch cycle: Operation cycle
Cd.22
New torque value/
forward new torque value
When "0" is set to " Cd.112 Torque change function switching request", a new
torque limit value is set. (This value is set to the forward torque limit value and
reverse torque limit value.)
When "1" is set to "
Cd.112 Torque change function switching request", a new
forward torque limit value is set.
Set a value within "0" to "
Pr.17
Torque limit setting value". Set a ratio against
the rated torque in percentage unit.
(The new torque value is invalid when "0" is set, and "
Pr.17
Torque limit setting
value" or "
Cd.101
" Torque output setting value" becomes valid. The range of
torque change is 1 to "
Pr.17
Torque limit setting value".)
Fetch cycle: Operation cycle