Chapter 9 Major Positioning Control
Restrictions
(1) An axis error (error code: 516) will occur and the operation cannot start if
"continuous positioning control" or "continuous path control" is set in
"
Da.1
Operation pattern".
(2) "Speed-position switching control" cannot be set in "
Da.2
Control system" of
the positioning data when "continuous path control" has been set in
"
Da.1
Operation pattern" of the immediately prior positioning data. (For
example, if the operation pattern of positioning data No. 1 is "continuous path
control", "speed-position switching control" cannot be set in positioning data
No. 2.) An axis error (error code: 516) will occur and the machine will carry out
a deceleration stop if this type of setting is carried out.
(3) An error (error code: 503) will occur if "current speed (-1)" is set in
"
Da.8
Command speed".
(4) If the value set in "
Da.6
Positioning address/movement amount" is negative, an
error (error code: 530) will occur.
(5) Even though the axis control data "
Cd.23
Speed-position switching control
movement amount change register" was set in speed-position switching
control (ABS mode), it would not function. The set value is ignored.
(6) To exercise speed-position switching control (ABS mode), the following
conditions must be satisfied:
(a) "
Pr.1
Unit setting" is "2: degree"
(b) The software stroke limit function is invalid (upper limit value = lower limit
value)
(c) "
Pr.21
Current feed value during speed control" is "1: Update current feed
value"
(d) The "
Da.6
Positioning address/movement amount" setting range is 0 to
359.99999 (degree)
If the value is outside of the range 0 to 359.99999 (degree), an error (error
code: 530) will occur at a start.
(e) The "
Pr.81
Speed-position function selection" setting is "2: Speed-position
switching control (ABS mode)".
(7) If any of the conditions in (6)(a) to (6)(c) is not satisfied in the case of (6)(e), an
error (error code: 935) will occur when the PLC READY signal [Y0] turns from
OFF to ON.
(8) If the axis reaches the positioning address midway through deceleration after
automatic deceleration started at the input of the speed-position switching
signal, the axis will not stop immediately at the positioning address. The axis
will stop at the positioning address after N revolutions so that automatic
deceleration can always be made. (N: Natural number)
In the following example, since making deceleration in the path of dotted line
will cause the axis to exceed the positioning addresses twice, the axis will
decelerate to a stop at the third positioning address.
Speed-position switching signal
positioning address
360 added
360 added
positioning address positioning address

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC-Q QD77MS and is the answer not in the manual?

Mitsubishi MELSEC-Q QD77MS Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC-Q QD77MS
CategoryControl Unit
LanguageEnglish

Related product manuals