EasyManuals Logo

Mitsubishi MELSEC-Q QD77MS User Manual

Mitsubishi MELSEC-Q QD77MS
976 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #585 background imageLoading...
Page #585 background image
10 - 22
Chapter 10 High-Level Positioning Control
[3] Multiple axes simultaneous start control procedure
The procedure for multiple axes simultaneous start control is as follows.
Cd.30 Simultaneous starting axis start
data No. (axis 1 start data No.)
Cd.31
Simultaneous starting axis start
data No. (axis 2 start data No.)
Set the following axis control data.
Write [9004] in " Positioning start
No.".
Cd.3
Turn ON the positioning start signal to be
started.
1)
2)
3)
When QD77MS2
Cd.30 Simultaneous starting axis start
data No. (axis 1 start data No.)
Cd.31
Simultaneous starting axis start
data No. (axis 2 start data No.)
Cd.32
Simultaneous starting axis start
data No. (axis 3 start data No.)
Cd.33
Simultaneous starting axis start
data No. (axis 4 start data No.)
Set the following axis control data.
When QD77MS4
Write [9004] in " Positioning start
No.".
Cd.3
Turn ON the positioning start signal to be
started.
1)
2)
3)
Cd.30
Simultaneous starting own axis
start data No.
Simultaneous starting axis start
data No.1
Simultaneous starting axis start
data No.2
Simultaneous starting axis start
data No.3
Set the following axis control data.
Cd.43
Simultaneous starting axis
Cd.31
Cd.32
Cd.33
When QD77MS16
Write [9004] in " Positioning start
No.".
Cd.3
Turn ON the positioning start signal to be
started.
1)
2)
3)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC-Q QD77MS and is the answer not in the manual?

Mitsubishi MELSEC-Q QD77MS Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC-Q QD77MS
CategoryControl Unit
LanguageEnglish

Related product manuals