13 - 84
Chapter 13 Control Sub Functions
[QD77MS4 operation example]
All axis servo ON
QD77 READY signal
V
t
Target position
BUSY signal
[X8]
n2n1 nx
Md.20 Current feed value
Error detection signal
[XC]
[X0]
[Y1]
[Y8]
PLC READY signal
[Y0]
Teaching is possible Teaching is possibleTeaching is impossible
Forward run JOG start
signal
(Note): Refer to Section 3.3 for input/output signal of QD77MS16.
2) Carry out the teaching operation with the following program.
No.20 Teaching program
Position to the target position with manual operation.
<Pulsate teaching command>
<Hold teaching command>
<Set teaching data>
<Set positioning data No.>
<Execute teaching>
<Turn OFF teaching command
memory>
M19PLS
ZP.TEACH1 "U0" D33 M34
477
488
492
M20
H0MOVP D35
M20SET
K3MOVP D36
M20RST
M19
X39
X0C
M34 M35
[QD77MS4 program example]
POINT
(1) Confirm the teaching function and teaching procedure before setting the positioning data.
(2) The positioning addresses that are written are absolute address (ABS) values.
(3) If the positioning operation is correctly completed with the written positioning data, it is
recommended that the positioning data be registered in the QD77MS flash ROM.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC-Q QD77MS and is the answer not in the manual?

Mitsubishi MELSEC-Q QD77MS Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC-Q QD77MS
CategoryControl Unit
LanguageEnglish

Related product manuals