Page #962 background imageLoading...
Page #962 background image
Appendix - 53
Appendices
Changed functions (Continued)
Specification
Function Description
QD77MS2 QD77MS4 QD77MS16 QD75MH2 QD75MH4
Da.16 Condition operator
Range of setting
value
01: **=P1
02: **
≠
P1
03: **
≤
P1
04: **
≥
P1
05: P1
≤
**
≤
P2
06: **
≤
P1,P2
≤
**
07: DEV=ON
08: DEV=OFF
10: Axis 1
selected
20: Axis 2
selected
30: Axis 1 and 2
selected
01: **=P1
02: **
≠
P1
03: **
≤
P1
04: **
≥
P1
05: P1
≤
**
≤
P2
06: **
≤
P1,P2
≤
**
07: DEV=ON
08: DEV=OFF
10: Axis 1
selected
20: Axis 2
selected
30: Axis 1 and 2
selected
40: Axis 3
selected
50: Axis 1 and 3
selected
60: Axis 2 and 3
selected
70: Axis 1, 2 and
3 selected
80: Axis 4
selected
90: Axis 1 and 4
selected
A0: Axis 2 and 4
selected
B0: Axis 1, 2 and
4 selected
C0: Axis 3 and 4
selected
D0: Axis 1, 3 and
4 selected
E0: Axis 2, 3 and
4 selected
01: **=P1
02: **
≠
P1
03: **
≤
P1
04: **
≥
P1
05: P1
≤
**
≤
P2
06: **
≤
P1,P2
≤
**
07: DEV=ON
08: DEV=OFF
01: **=P1
02: **
≠
P1
03: **
≤
P1
04: **
≥
P1
05: P1
≤
**
≤
P2
06: **
≤
P1,P2
≤
**
07: DEV=ON
08: DEV=OFF
10: Axis 1
selected
20: Axis 2
selected
30: Axis 1 and 2
selected
01: **=P1
02: **
≠
P1
03: **
≤
P1
04: **
≥
P1
05: P1
≤
**
≤
P2
06: **
≤
P1,P2
≤
**
07: DEV=ON
08: DEV=OFF
10: Axis 1
selected
20: Axis 2
selected
30: Axis 1 and 2
selected
40: Axis 3
selected
50: Axis 1 and 3
selected
60: Axis 2 and 3
selected
70: Axis 1, 2 and
3 selected
80: Axis 4
selected
90: Axis 1 and 4
selected
A0: Axis 2 and 4
selected
B0: Axis 1, 2 and
4 selected
C0: Axis 3 and 4
selected
D0: Axis 1, 3 and
4 selected
E0: Axis 2, 3 and
4 selected
Da.18 Parameter 1
Range of setting
value
Set by "
Da.16 Condition operator".
Set by "
Da.16
Condition operator"
and "
Da.23
Number of
simultaneously
starting axes
".
Set by "
Da.16 Condition operator".
Da.19 Parameter 2
Range of setting
value
Set by "
Da.16 Condition operator".
Set by "
Da.16
Condition operator"
and "
Da.23
Number of
simultaneously
starting axes
".
Set by "
Da.16 Condition operator".

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC-Q QD77MS and is the answer not in the manual?

Mitsubishi MELSEC-Q QD77MS Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC-Q QD77MS
CategoryControl Unit
LanguageEnglish

Related product manuals