EasyManua.ls Logo

MLC LC100 - Page 104

MLC LC100
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
104
LC100 Instruction manual
4/6 Parameters
9/12 Protection
Type I
I-12
Temperature for switching the control board fan ON
0-85°C
Parameter for setting the temperature for control board fan. If the procesor
temperature reaches the set value the output with the function FO-35 is
switched on. Output for control board fan stays active until the temperature
falls below the value set in I-13.
I-13
Temperature for switching the control board fan OFF
0-85°C
Parameter for setting the temperature for switching off the control board fan.
I-14
Conditions reset
A After activating end limit switch for automatic drive reset is required
B After activating car lock deivce for automatic drive reset is required.
C After activating service pit doors for automatic drive reset is required.
D After service drive from the cabin for automatic drive reset is required.
E After service drive from the pit for automatic drive reset is required.
F After „Start failure ID-64“ for automatic drive reset is required.
G After car or landing door contact error has ocurded drive reset is required.
H After contactors turning on failure for automatic drive reset is required
I-15
Conditions mode
A not selected on the service drive stop on the reference switch.
selected - On the service drive stop on stopping magnet (with low speed
after reference switch).
B not selected - levelling speed before reference switch on recall travel.
selected - Service speed 1(C-7) before reference switch on recall travel.
C not selected - levelling speed after reference switch on recall travel.
selected - Service speed 1(C-7) after reference switch on recall travel.
D enable doors opening with service buttons on the cabin.
E enable doors opening on the recall drive with buttons for driving if elevator
is in the floor level
F Recall travel are not possible without vertical position of pillar in the pit
(FI-309)
G reserved
H reserved

Table of Contents