LC100 Instruction manual
NO
DYSPLAY ON LC100-D
DESCRIPTION
FO-031
End of fire program function. Function is on when fire program has ended.
FO-032
Function for controlling the shaft light. Function is on when inspection drive is
on, and turned off when turned back to normal drive and time H-05 expired.
Function is not working if the function elevator test FI-219 is on.
FO-033
Output function for time relay 1. Setting of the relay is explained in the
parameters type H.
FO-034
Output function for time relay 2. Setting of the relay is explained in the
parameters type H.
FO-035
Output function for control panel fan managment.
FO-036
Output function for brake opening in evacuation.
FO-037
Output function is active in case UCM fault.
FO-038
Output function is active in case “Pillion in shaft” FI-309.
FO-039
Output function is active in case “Landing door N=1” FI-308.
FO-040
Open door A command
FO-041
Close door A command.
FO-042
Low speed command to door A. It is used for frequency regulated cabin doors.
Function is activated according to the functions FI-266 or FI-267.
FO-043
Function for controling the resistor for reversing the cabin doors A. Function
is used for doors with spindle. When reversing the doors power for the doors
is given through resistors. Time for this function can be set through parameter
D-35.
FO-044
Open door B command
FO-045
Close door B command.
FO-046
Low speed command to door B. It is used for frequency regulated cabin doors.
Function is activated acording to the functions FI-266 or FI-267.
FO-047
Function for controlling the resistor for reversing the cabin doors B. Function
is used for doors with spindle. When reversing the doors power for the doors
is given through resistors. Time for this function can be set through parameter
D-35.
FO-048
Function for managment the retaring cam. Function is active during drive.
FO-049
Low voltage control for retaring cam.
FO-050
Cabin fan control function. It is activated acording to the type of control
parameter H-01. Engage time for fan is defined by parameter H-02.
FO-051
Cabin light control function. It is activated acording to the type of control
parameter H-03. Engage time for cabin light is defined by parameter H-03.
FO-052
New stop output function. Function is impulse after changihg the floor.
Engage time of the function is when cabin pass by counting switch.
FO-053
Alarm enable function. Function is active when the car is at floor and the doors
are opened.
FO-054
New cabin call function. Function is impulse and it is triggered every time
when cabin call is activated.
FO-055
Stopping impulse function. Funcition is triggered when elevator is slowing
down when cabin pass by counting switch for selected floor.
FO-056
Function active when elevator is out of order.
FO-057
Output function for energy saving mode.
FO-058
Output for powering the overspeed governor coil or for AMI safety device
For enable work with AMI device (H-20 > 0).
FO-059
Phase sequence are correct.
FO-060
Reserved direction up signalization.
FO-061
Reserved direction down signalization.