End of fire program function. Function is on when fire program has ended.
Function for controlling the shaft light. Function is on when inspection drive is
on, and turned off when turned back to normal drive and time H-05 expired.
Function is not working if the function elevator test FI-219 is on.
Output function for time relay 1. Setting of the relay is explained in the
parameters type H.
Output function for time relay 2. Setting of the relay is explained in the
parameters type H.
Output function for control panel fan managment.
Output function for brake opening in evacuation.
Output function is active in case UCM fault.
Output function is active in case “Pillion in shaft” FI-309.
Output function is active in case “Landing door N=1” FI-308.
Low speed command to door A. It is used for frequency regulated cabin doors.
Function is activated according to the functions FI-266 or FI-267.
Function for controling the resistor for reversing the cabin doors A. Function
is used for doors with spindle. When reversing the doors power for the doors
is given through resistors. Time for this function can be set through parameter
D-35.
Low speed command to door B. It is used for frequency regulated cabin doors.
Function is activated acording to the functions FI-266 or FI-267.
Function for controlling the resistor for reversing the cabin doors B. Function
is used for doors with spindle. When reversing the doors power for the doors
is given through resistors. Time for this function can be set through parameter
D-35.
Function for managment the retaring cam. Function is active during drive.
Low voltage control for retaring cam.
Cabin fan control function. It is activated acording to the type of control –
parameter H-01. Engage time for fan is defined by parameter H-02.
Cabin light control function. It is activated acording to the type of control –
parameter H-03. Engage time for cabin light is defined by parameter H-03.
New stop output function. Function is impulse after changihg the floor.
Engage time of the function is when cabin pass by counting switch.
Alarm enable function. Function is active when the car is at floor and the doors
are opened.
New cabin call function. Function is impulse and it is triggered every time
when cabin call is activated.
Stopping impulse function. Funcition is triggered when elevator is slowing
down – when cabin pass by counting switch for selected floor.
Function active when elevator is out of order.
Output function for energy saving mode.
Output for powering the overspeed governor coil or for AMI safety device
For enable work with AMI device (H-20 > 0).
Phase sequence are correct.
Reserved direction up signalization.
Reserved direction down signalization.