LC100 Instruction manual
NO
DYSPLAY ON LC100-D
DESCRIPTION
FI-293
Aditional input function for elevator with short pitt . After input FI-293 is active
elevator is blocked until reset on the LC100-D keypad or activating FI-372.
Function is identical as function FI-206.
FI-294
Input for open door button for both cabin doors „A“ and „B“
FI-295
Input for close door button for both cabin doors „A“ and „B“
FI-296
Input function for disabeling the calls defined by the parameter B-17.
FI-297
Input for power supply control phase „R“
FI-298
Input for power supply control phase „S“
FI-299
Input for power supply control phase „T
FI-300
Input for controlling the UMD safety device.
FI-301
Input function for activating output function FO-92.
FI-302
Input function for activating output function FO-93.
FI-303
Input function for earthquake program. Elevator stops in the nearest floor and
stays with the open doors until input is deactivated.
FI-304
Input for leveling speed control.
FI-305
Input function for door A opening in case of automatic evacuation.
FI-306
Input function for door B opening in case of automatic evacuation.
FI-307
Input for activating the lift boy program.
FI-308
Input for control of the landing door contact for the first floor door, used in
elevators with the short pit space.
FI-309
Input for control of the pillion in the pitt, used in elevators with the short pit
space.
FI-310
Input for controlling the aditional valve for down drive.
FI-311
Input for control of the UPS..
FI-312
Input for active function for testing norme 2454-2.
FI-313
Input for control of the Bucher I-Valve. *condition for enable I-valve mode are
parameters C-22 or C-23 <> #0
FI-314
Input for control of the landing door contact for the first floor.
FI-315
Input for control of the landing door contact for the second floor.
FI-325
Input for control of the landing door contact for the twelfth floor.
FI-326
Input for activating automatically entrance on the cabin roof for service drive.
FI-327
Input for reset small pit status.
FI-328
Inspection drive from the pit input.
FI-329
Inspection drive from the pit, up input function.
FI-330
Inspection drive from the pit, down input function.
FI-331
Input for limit service switch UP 2 meters beffore station.
FI-332
Input for limit service switch DOWN 2m meters beffore station.
FI-333
Input for control bridging safety chain.