LC100 Instruction manual
4/6 Parameters
12/12 Factory
Type T
T-07
Next service MONTH
0-12
Function is used for elevators with surveillance system to keep track for
servicing the elevators. Parameter T-06 is for setting the day in the month,
parameter T-07 is for setting the month and T-08 is for setting the year.
T-08
Next service YEAR
0-99
Function is used for elevators with surveillance system to keep track for
servicing the elevators. Parameter T-06 is for setting the day in the month,
parameter T-07 is for setting the month and T-08 is for setting the year.
T-09
Monitoring type
0/1
Monitoring type (filtering the parameters):
0 on parameter filtering is switched off.
1 off parameter filtering is switched on.
When the filtering is switched off all parameters of the system are visible
through the LC100-D terminal.
When the filter is „on“ parameters and functions are visible according to each other. If some parameters are
not reacheable that means the filter is „on“.
Example 1: If the parameter Main driveis set to C-01=3 (frequency regulated elevator). Then all other
parameters that are related are visible (C-02, C-03 ... C-12, C-13), while all other parameters are
not visible (C-14, C-15, C-16, C-17 parameters for hydraulic elevators).
Example 2: If the parameter Cabin dooris set to D-01=1 (one automatic door). Then all parameters for door
A are visible and parameters for door B are hidden.
Example 3: Parameter „Number of stops“ is set to A-01=7 (elevator with 7 floors). Then for cabin calls is
possible to set only seven calls, and all other parameters that are for higher floors are not visible.
T-10
CAN frequency
0-99
Parameter for changing the CAN baudrate.