Passenger passing time after cabin call
Passenger passing time after new cabin call while in station.
By giving new cabin command passenger passing time is set by parameter.
Parameter is used to activate input function FO-42 (for A door) or FO-46 (for
B door) with doors with no before end-switches. Parameter estimates the time
of opening or closing the door and activates a low speed depending on the
parameter.
Parameter is time with no active commands for open and close door while
reversing.
The parameter is the time of the resistors to reduce the mechanical strain of
the door if resistor function is in use FO-43 for A-side door, FO-47 for B-side
door.
After door lock acivating, system filtrates input for stabilizing door lock contact
and starts traveling after filter set by parameter. The parameter is used to
prevent safety circuit break after start command.
Flaster effect ligh curtain A
The parameter is the time how long input FI-263 “Photocell door A” can be
active before starting door nudging.
Flaster effect ligh curtain B
The parameter is the time how long input FI-273 “Photocell door B” can be
active before starting door nudging.