10/05 AWB8230-1541GB
Holding register (word
variable)
181
117C H034 Reserved rw – –
117D – Reserved rw – –
117E H050 Reserved rw – –
117F H051 Reserved rw – –
1180 H052 Reserved rw – –
1181 H060 Reserved rw – –
1182 H070 Reserved
rw – –
1183 H071 Reserved rw – –
1184 H072 Reserved rw – –
1185 H080 Reserved
rw – –
1186 H081 Reserved
rw – –
1187 Reserved – – –
…
1500
1501 F202 Acceleration time 1 (second
parameter set) (MSB)
rw 0.01 – 99.99 (0.01 s)
100.0 – 999.9 (0.1 s)
1000 – 3000 (1 s)
0.01 [s]
1502 F202 Acceleration time 1 (second
parameter set) (LSB)
1503 F203 Deceleration time 1 (second
parameter set) (MSB)
rw 0.01 – 99.99 (0.01 s)
100.0 – 999.9 (0.1 s)
1000 – 3000 (1 s)
0.01 [s]
1504 F203 Deceleration time 1 (second
parameter set) (LSB)
rw
1505 – Reserved rw – –
…
1509
150A A201 Frequency reference value
source selection (second
parameter set)
rw 00: Potentiometer (keypad) –
01: Analog input: Control signal terminals O
and OI
02: Digital input (function PNU F001 or A020)
and keypad
03: Serial interface (Modbus)
10: Calculator (calculated value of CAL)
150B A202 Start signal source selection
(second parameter set)
rw 01: Digital input (FWD/REV) –
02: START button (keypad)
03: Serial interface (Modbus)
04: Potentiometer (keypad)
150C A203 Base frequency
(second parameter set)
rw 30 – 400 Hz, up to value of PNU A004 [Hz] 1 [Hz]
150D A204 End frequency (fmax)
(second parameter set)
rw 30 – 400 Hz 1 [Hz]
150E A220 Reserved rw –
Holding
register
Function
code
Name
Access
rights
Value range Manipulated
variable
hex