Communications Card Description ZB4-604-IF1, PROFIBUS-DP 5-10
Moeller 07/01 AWB-C2700-1347GB
7.2 Profile driver number 2
This profile contains 2 modules:
Modul0 = 0: (Moeller PS416)
Profile 0 has 38 bytes of input and output data.
With the profile header this results in 33 bytes of input user data and 35 bytes of output user data
according to the following specification.
Modul1 = 1: (Moeller PS416)
Profile 0 has 70 bytes of input and output data:
With the profile header this results in 65 bytes of input user data and 67 bytes of output user data
according to the following specification.
Data request of MMI:
Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 37 (69)
Job number Operation Offset Low Offset High Data Len Data 0 Data n Data 32 (64)
The job number is incremented by 1 with every request.
Response of Masters:
Byte 0 Byte 1 Byte 2 Byte 37 (69)
Job number Status flag/
Error code
Data 0 Data n Data 34 (66)
The responses of the master contain the same job number as the corresponding request.
Operation codes:
0x10 Read bytes (request information from master)
0x40 Do nothing
0x90 Send bytes (send information to master)
The status flag is reserved for future applications.