Device Description MV4-150-TA1, MV4-450-TA1, MV4-170-TA1, MV4-470-TA1 1-12
Moeller 07/01 AWB-C2700-1347GB
5 Mounting instructions
5.1 Mounting according to degree of protection IP 65
a) Installation of the unit with 4-hole aluminium front
For installation requiring IP 65 compliance the supplied conter frame and seal must be used. These ensure
that the necessary pressure is applied to the seal when mounting the unit in thin-walled front panels .
Special care should be taken during mounting to ensure correct sealing to IP 65.
1. Fit the front seal from the rear of the device.
2. Insert the unit into the panel cutout from the front (without any force).
3. The front seal must fit evenly between the front plate and the front panel.
4. Fit the conter frame from the rear of the device.
5. Tighten the countersunk screws on the device through the front panel onto the conter frame.
The countersunk screws must be tightened uniformly and securely.
6. Ensure the correct positioning and even pressure of the front seal.
Observe the general mounting instructions (see Section 4).
IP 65 can only be guaranteed with correct mounting.