4 - 12 MC40 Integrator Guide
symbols that include a modulo 43 check digit. Enable this feature only if the Code 39 symbols contain
a modulo 43 check digit (default - disabled).
•
Report Check Digit - Transmit Code 39 data with or without the check digit. A check in the checkbox
indicates to send Code 39 data with check digit (default - disabled).
•
Full ASCII - Code 39 Full ASCII is a variant of Code 39 that pairs characters to encode the full ASCII
character set. To enable or disable Code 39 Full ASCII (default - disabled),
•
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the
checkbox indicates that redundancy is enabled (default - disabled).
•
Convert Code39 To Code32 - Code 32 is a variant of Code 39 used by the Italian pharmaceutical
industry. Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32
(default - disabled).
•
Report Code32 Prefix - Scan the appropriate bar code to enable or disable adding the prefix
character “A” to all Code 32 bar codes (default - disabled).
•
Security Level - Options: Security level 0, Security Level 1, Security Level 2 and Security Level 3
(default - Security level 1).
•
Interleaved 2of5
•
Length1 - Use to set decode lengths (default - 14). See Decode Lengths on page 4-15 for more
information.
•
Length2 - Use to set decode lengths (default - 10). See Decode Lengths on page 4-15 for more
information.
•
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the
checkbox indicates that redundancy is enabled (default - enabled).
•
Check Digit
• No Check Digit - A check digit is not used. (default)
• USS Check Digit - Select to check the integrity of all Interleaved 2 of 5 symbols to verify the data
complies with either the Uniform Symbology Specification (USS) check digit algorithm.
• OPCC Check Digit - Select to check the integrity of all Interleaved 2 of 5 symbols to verify the data
complies with either the Optical Product Code Council (OPCC) check digit algorithm.
•
Report Check Digit - Transmit Interleaved 2 of 5 data with or without the check digit. A check in the
checkbox indicates to send I2of5 data with check digit (default - disabled).
•
Convert ITF-14 To EAN13 - Convert 14-character Interleaved 2 of 5 bar codes to EAN-13, and
transmit as EAN-13. The Interleaved 2 of 5 bar code must be enabled and must have a leading zero
and a valid EAN-13 check digit. A check in the checkbox indicates that the option is enabled (default -
disabled).
•
Composite AB
•
UCC Link Mode
• Link Flag ignored - 1D component is transmitted regardless of whether a 2D component is
detected.
• Always Linked - 1D and the 2D components are transmitted. If 2D is not present, the 1D
component is not transmitted.
• Auto Discriminate - the digital scanner determines if there is a 2D portion, then transmits the 1D
component, as well as the 2D portion if present. (default).
•
UK Postal
•
Report Check Digit - Transmit UK Postal data with or without the check digit. A check in the
checkbox indicates to send UK Postal data with check digit (default - disabled).