4 - 18 MC40 Integrator Guide
Track Selection
There are up to three tracks of encoded data on a magnetic stripe. This option selects the tracks that will be
read and decoded.
Any Track - All tracks on the magnetic stripe are read and decoded by the MSR.
Require Track 1 Only - Only track 1 on the magnetic stripe is read and decoded by the MSR.
Require Track 2 Only - Only track 2 on the magnetic stripe is read and decoded by the MSR.
Require Track 1 & Track 2 - Only tracks 1 and 2 on the magnetic stripe are read and decoded by the
MSR.
Require Track 3 Only - Only track 3 on the magnetic stripe is read and decoded by the MSR.
Require Track 1 & Track 3 - Only tracks 1 and 3 on the magnetic stripe are read and decoded by the
MSR.
Require Track 2 & Track 3 - Only tracks 2 and 3 on the magnetic stripe are read and decoded by the
MSR.
Require All Three Tracks - All tracks on the magnetic stripe are read and decoded by the MSR.
Any Track 1 & 2 - Either track 1 or 2 on the magnetic stripe are read and decoded by the MSR.
Any Track 2 & 3 - Either tracks 2 or 3 on the magnetic stripe are read and decoded by the MSR.
Track Separator
Use Track Separator to add a character between decoded data. (default - 0Dh CR (carriage return)).
Sentinel/track 2 data
The MSR can be set to either send, or not send, the Start/End sentinel, and to send either the Track 2 account
number only, or all the encoded data on Track 2. The Track 2 setting does not affect the output of Track 1 and
Track 3.
Don’t send start/end sentinel and send all data on Track 2 - Do not send Sentinel data and send all
Track 2 data.
Send start/end sentinel and send all data on track 2 - Send Sentinel data and send all Track 2 data.
Don’t send start/end sentinel and send account number on Track 2 - Do not send Sentinel data and
only send account number data from Track 2.
Send start/end sentinel and send account number on Track 2 - Send Sentinel data and only send
account number data from Track 2.
Keystroke Output
Use to configure the Keystroke Output Plug-in for the profile.
Enabled - Enables or disables this plug-in. A check in the checkbox indicates that the plug-in is
enabled (default - enabled).
Action key character - Enabled decoding a special characters embedded within a bar code or MSR
data.
None - Action key character feature is disabled (default).
Tab - Tab character (\t) in a bar code is processed.
Line feed - Line feed character (\t) in a bar code is processed.

Table of Contents

Other manuals for Motorola MC40

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola MC40 and is the answer not in the manual?

Motorola MC40 Specifications

General IconGeneral
BrandMotorola
ModelMC40
CategoryHandhelds
LanguageEnglish

Related product manuals