9. The Serial Parameters tab in the following figure show the default settings when the OnCell G3100 is
powered on. However, the program can redefine the serial parameters to different values after the program
opens the port with Win32 API.
10. Click the Security tab to configure security settings. Select the Enable Data Encryption option to enable
data to be encrypted when transmitted over the COM ports. After selecting the encryption option, select the
Keep connection option to start encrypting COM port communications immediately without restarting the
COM ports. (If your application opens and closes COM ports frequently and the OnCell G3100 is only for one
host, you can enable this option to speed up the opening/closing time. However, this will result in your host
tying up the COM port so that other hosts cannot use it.) Select the Apply All Selected Ports option to
enable the security settings to be applied to all COM ports.