Chapter 5: Programming 5-35
Tone Frequency
ThisparameterpermitsyoutosetthefrequencyoftheCode128tone.Setthis
parameterbyscanningtheappropriateHextag(Hex0 to
Hex7).
Hex Tag Frequency in Hertz
Hex0 702Hz
Hex1 781Hz
Hex2 868Hz
Hex3 961Hz
Hex4 1071Hz
Hex5 1187Hz
Hex6 570Hz
Hex7 633Hz
Note: ThedefaultCode128tonefrequencyis1071Hertz(Hex4).
Code 128 Stitch Enable
ThisparameterdetermineswhetherCode128tagstitchingisenabledordisabled.
ScantheHexCtodisableCode128Stitching(default)orHexDtoenableit.
Scans Required
ThisparametersetsthenumberofscansrequiredtoreadaCode128barcode.
Increasingthenumberofscanscanimprovereadingnominalbarcodes.Thereare
foursettings:1scan,2scans,3scans,and4scans.Thedefaultis1scan.Setthis
parameterbyscanningtheappropriate
Hextag(Hex1toHex4).
Overlap Characters
Thisparametersetstheminimumnumberofcharacterswhicheachsegmentmust
containwhentagstitchingisdone.Therearefoursettings:1overlapcharacter(Hex
1),2overlapcharacters(Hex2)(default),3overla pcharacters(Hex3),and4overlap
characters
(Hex4).Setthisparameterbyscanning
theappropriateHextag(Hex1toHex4).
Minimum Segment Size
Thisparametersetstheminimumnumberofcharacterswhicheachsegmentmust
containwhentagstitchingisdone.Setthisparameterbyscanningtheappropriate
Hextag(Hex2toHex9).Thedefaultis
Hex4.