Chapter 5: Programming 5-95
Volume Levels
ThereareeightstandardvolumesettingsintheRealScan74.However,thereisa
programmingsequencewhichactivateseleven.Thisgivestheoperatorgreater
flexibilityinselectingtheappropriatevolumeoftheGoodreadTone.Thisparameter
doesnothaveadefaultvalue,however,theRealScan74isshippedfromthe
factory
withthisparameterdisabled.ThedefaultsettingoftheRealScan74iseightvolume
levels.
•
Enable—ProgramMode,Hex4,Hex2,Hex5,andSaveandReset
•
Disable—ProgramMode,Hex4,Hex2,Hex4,andSaveandReset
Enable/Disable Volume Adjust Button
Throughprogramming,theVolumeAdjustbuttoncanbeenabledordisabled.If
disabled,theGoodReadtonevolumeandtonearesetusingthevarious
programmingtags;andpressingthebuttondoesnotchangetheGoodReadtone.If
theVolumeAdjustButtonisdisabled,besuretosetthevolume,
tone,andtonelength
tothedesiredsettingsfirst.
Note: ScanningtheDefaulttagenablestheVolumeAdjustButton.
•
Enable—ProgramMode,Hex3,HexE,Hex1,andSaveandReset
•
Disable—ProgramMode,Hex3,HexE,Hex0,andSaveandReset
Enable Volume Adjust Button
ToenabletheVolumeAdjustbutton,scanthefollowingsequence ofprogramming
tags.ThesetagsmustscannedfirstafterapplyingpowertotheRealScan74.
1.
ProgramMode—putsscannerintheprogrammingmode
2.
Hex3,HexE,Hex1—enablestheVolumeAdjustbutton
3.
SaveandReset—storestheenabledsetting,andthenresetsthescanner
Disable Volume Adjust Button
TodisabletheVolumeAdjustButton,scanthefollowingsequenceofprogramming
tags.ThesetagsmustscannedfirstafterapplyingpowertotheRealScan74.This
sequencesetstheGoodReadtonefrequency(tone),length,andvolume.
1.
ProgramMode—startsthescannerintheprogrammingmode.
2.
Hex1,Hex1—sendsprogrammingtotheGoodReadToneparameters
3.
HexA,Hex1—turnsontheGoodReadtoneincaseitwaspreviouslyturnedoff
4.
HexB—repeatedlyscanthistaguntilyoureachthedesiredtonefrequency(tone)
5.
HexC—repeatedlyscanthistaguntilyoureachthedesiredtonelength
6.
HexD—repeatedlyscanthistaguntilyoureachthedesiredtonevolume