Chapter 5: Programming 5-91
GS1 Databar–Expanded
GS1Databar–Expandedisavariablelengthlinearsymbology.Itcanencode74
numericor41alphacharacters.RSSExpandedcanbescannedanddecodedinupto
22segmentsandthenreconstructed
19256
9987 6543 2101 2345 6789 8888
GS1 Databar–Expanded Stacked
GS1Databar–ExpandedStackedissimilartoGS1Databar–14Stackedexceptituses
theGS1Databar–Expandedformatforcreatingthesymbol.
19257
0192 1234 5698 7457 3202 0000 9939 0200 296
Enable/Disable GS1 DataBar
GS1DataBarpermitsmoredatatoberecordedinasmallerphysicalspace.The
RealScan74canbeprogrammedtoreadGS1DataBartags.Whenprogrammingthe
GS1DataBarfeature,theprogrammingtagsmustbethefirsttagsscannedafter
applyingpowertotheRealScan74.
Enable—ProgramMode,Hex1,Hex8,HexA,Hex3,SaveandReset.
Disable—ProgramMode,Hex1,Hex8,HexA,Hex0,SaveandReset.
Send GS1 DataBar–14 as EAN–13 Data
Whenenabled,thescannersendsthelast13digitsofthe
GS1DataBar–14datatothehostterminal.TheDefaulttagdoesnotchangethis
parameter.
Enable—ProgramMode,Hex6,Hex0,Hex5,andSaveandReset.
Disable—ProgramMode,Hex6,Hex0,Hex4,andSaveandReset.