Chapter 3: Installation 3-37
25592
Label Identifiers
EAN13
EAN8
UPC-E
UPC-A
Code 39
I 2 of 5
Code 128
UCC/EAN128
= "A" (41h)
= "B" (42h)
= "C" (43h)
= "A0" (41h 30h) (UPC-A is expanded into EAN13
= "M" (4Dh)
= "I" (49h)
= "K" (4Bh)
= "P" (50h) (UCC/EAN128 Label ID is enabled
Codabar
Pharmacode
= "N" (4Eh)
= "A" (41h)
Peripheral Connections
PleasebeawarethattheseHand‐HeldsetupinstructionsassumeCode128,Code39
andInterleaved2of5areenabledontheRealScan74.Otherwise,ifanyofthosebar
codetypesarescannedwithanyoftheHand‐Helds,andtheyarenotalsoenabledon
theRealScan74,
thentheRealScan74producesa“bad”toneandwillNOTtransmit
thebarcodedata.
Metrologic Hand-Held Scanner
AMetrologicHand‐HeldScannercanbeconnectedtooneofthe
RS232auxiliaryportsontheNCRRealScan74.IftheMetrologicHand‐Heldisthe
onlyperipheraldevice,itcanbeconnectedtoeitherport.However,ifconnecting
anotherperipheraldevice,theremayberestrictionsfortheMetrologicport
connection.
Note: ThesewererecentlytestedonaMetrologicVoyager
(MetrologicMS9540)andworked.However,eachadditionalmodelneedstobe
verified.
Metrologic
RealScan 74
25789
Cable: 53-53220A
No external power needed