Chapter 3: Installation 3-31
ScanthefollowingEASCommunicationsFunctiontagtosettheEASCommunication
function.
Thefunctionchangeseachtimethistagisscanned.Thenumberofbeepsindicates
howthefunctionisset.
1Beep—EASCommunicationsfunctionisdisabled—Factorydefault
2Beeps—RealScan74sendsErrorbarcode(048589999999)
3Beeps—RealScan74sendsErrorbarcode(048589999999)andDetectbarcode
(048589999988)
4Beeps—RealScan74sendsDetectbarcode(048589999988)
ThefollowingtagincrementstheErrorbarcodetimer.Eachtimethetagisread,the
timeisincremented½seconduntilthemaximumtimeisreached.Itthenstartsover
withtheleasttime.
Thenumberofbeepsindicateshowthetimerisset.
1Beep—½second
2Beeps—1second
3Beeps—1½seconds
4Beeps—2seconds
5Beeps—2½seconds
6Beeps—3seconds
7Beeps—3½seconds
8Beeps—4seconds