EasyManuals Logo

NCR VOYIX CX7 User Manual

NCR VOYIX CX7
242 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #107 background imageLoading...
Page #107 background image
Confidential and proprietary information of NCRCorporation.
Unauthorized use, reproduction and/or distribution is strictly prohibited.
107
Configuring Cash Drawer Switch Polarity
Configuring the cash drawer switch polarity depends on the platform software package
used. For more information, refer to:
l
Gen3 below
l
RPSW on page109
l
RPSL on page111
l
NCRPSW/NCRPSL on page112
Gen3
Hospitality (HSR) cash drawers all use 12V coils with Normally Open detection switches.
By default, the Gen3 Hospitality platform software open/close sense settings is Normally
Open. To use a drawer with Normally Closed detection switches (for example, Retail 24V
drawer), the sense settings can be reversed through registry settings.
Note
Gen3 does not support Printer Cash Drawers.
For 64-bit operating systems
To change the sense settings for a 64-bit Operating System, configure the following
registry values.
Normally
Open
Switch
Polarity
(Default)
Normally Closed
Switch Polarity
Registry Action Action
Terminal
Cash
Drawer 1
HKLM/Software/Wow6432Node/Radiant/
Platform/CashDrawer/ReverseOpenDetect1
Delete the
DWORD
registry
value or set
the value of
the
DWORD to
0.
1. Create a
new
DWORD
registry
value.
2. Set the
value of the
new
DWORD to
1.
Terminal
Cash
Drawer 2
HKLM/Software/Wow6432Node/Radiant/
Platform/CashDrawer/ReverseOpenDetect2

Table of Contents

Other manuals for NCR VOYIX CX7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NCR VOYIX CX7 and is the answer not in the manual?

NCR VOYIX CX7 Specifications

General IconGeneral
BrandNCR
ModelVOYIX CX7
CategoryTouch terminals
LanguageEnglish