EasyManua.ls Logo

NCR VOYIX CX7 - Rpsw; Opos; Configuring through RSM le Utility; Configuring through Windows Registry

NCR VOYIX CX7
242 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Confidential and proprietary information of NCRCorporation.
Unauthorized use, reproduction and/or distribution is strictly prohibited.
109
RPSW
By default, the RPSW open/close sense setting is Normally Closed. RPSW cash drawer
polarity settings can be configured in either of two ways:
l
through the RSM LE utility—for both OPOS and JavaPOS
l
through the registry:
l
Windows registry—for OPOS
l
config.xml settings—for JavaPOS
OPOS
Configuring through RSMLEutility
To change the sense settings in the RSMLEutility, configure the value of the following
parameters.
Normally Open
Switch Polarity
Normally Closed
Switch Polarity
(Default)
Parameter Name Parameter Value Parameter Value
Terminal Integrated Cash
Drawer
Model Integrated_Open (None)
Printer Cash Drawer Invert CashDrawer Status True False
Configuring through Windows Registry
To change the sense settings in the Windows Registry, set the registry value.
Normally
Open Switch
Polarity
Normally
Closed
Switch
Polarity
(Default)
Registry Value Value
Printer Cash
Drawer
HKLM\SOFTWARE\Wow6432Node\OLEForRetail\
ServiceOPOS\CashDrawer\<ProfileName>\
InvertCDPolarity
T F