Confidential and proprietary information of NCRCorporation.
Unauthorized use, reproduction and/or distribution is strictly prohibited.
110
Note
There are two configurations for InvertCDPolarity for RPSW in OPOS—one in the
cash drawer-printer profile and one in the printer profile. When either one is
updated, it should reflect on both profiles.
JavaPOS
Configuring through RSMLEutility
To change the sense settings in the RSMLEutility, configure the value of the following
parameters.
Normally Open
Switch Polarity
Normally Closed
Switch Polarity
(Default)
Parameter Name Parameter Value Parameter Value
Terminal Integrated Cash
Drawer
Model Integrated_Open (None)
Printer Cash Drawer Invert CashDrawer Status True False
Configuring through config.xml settings
To change the sense settings in config.xml, go to C:\ProgramData\NCR\NCR
JavaPOS\jpos\res\config.xml and configure the following registry values.
Normally Open
Switch Polarity
Normally Closed
Switch Polarity
(Default)
Registry Name Value Value
Terminal Integrated Cash
Drawer
Model Integrated_Open (None)
Printer Cash Drawer InvertCDPolarity T F