Installing the Cash Drawer
The Cash Drawer can be connected to the Cash Drawer connector on the Base.
Warning
Non-NCRCash Drawers must contain a protective diode.
The table below shows the cable options.
Cable Description Notes
1432-C516-0009 Dual Cash Drawer Splitter for 24V
cash drawers
Required if using two 24V cash drawers
on a CX7 USBCentric I/O.
1432-C517-0009 12V Cash Drawer (RJ12) Adaptor for
Single or Dual Cash Drawer
Required if using 12V cash drawers
(legacy Radiant) on a CX7 USBCentric
I/O. Cable allows software to see which
drawer is open/closed.
1432-C828-0010 CX7 Single Cash Drawer 6-pin to 4-
pin (12V) Cable
Required if using 12V cash drawer on a
CX7 USBCentric I/O or Serial Centric
I/O .
The table below shows the cable needed per configuration.