Voice Mail Overflow
IntraMail for Aspire System Guide Chapter 2: Features 183
2
Programming Department Calling Group Overow for a DIL to the Master Number
Step 1 Set up the Department Group.
1.1 16-02-01: Department Group Assignment for Extensions.
- Assign telephone extensions to a Department Group.
By default:
- Telephone extensions are assigned to Department Group 1.
- IntraMail extensions (343-350) are assigned to Department Group 8.
1.2 11-07-01: Department Group Pilot Numbers
- Assign master (pilot) numbers to Department Groups.
By default:
- The IntraMail Department Group (8) uses master number 700.
- No other Department Group master numbers are assigned.
Step 2 Set up a DIL for the Department Group.
2.1 22-02-01: Incoming Call Trunk Setup
- Assign Service Type
4 to each trunk you want to be a DIL. Make a separate entry for each
Night Service mode.
By default, trunks are Service Type 0 (Normal).
2.2 22-07-01: DIL Assignment
- For each DIL you want to ring the Department Group directly, enter the Department Group
master number.
By default, there are no DIL destinations programmed.
2.3 22-08-01: DIL/IRG No Answer Destination
- For each DIL to the Department Group master number, enter
102 to make IntraMail the
overow (no answer) destination.
By default, the overow (no answer) destination is Incoming Ring Group 1.
Step 3 Set how long a DIL will ring in the Department Group before overow occurs.
3.1 22-01-04: DIL No Answer Recall Time
- Set how long (
0-64800 seconds) the DIL will ring in the Department Group before over-
ow occurs.
By default, this interval is 0 (no overow).
Step 4 Set up the Department Group Master Mailbox.
4.1 47-03-01: Master Mailbox Active on page 206.
- Be sure the Master Mailbox is active (
1).
By default, all Master Mailboxes are inactive.
4.2 47-03-02: Master Mailbox Number on page 206.
- The Master Mailbox number must be the same as the Department Group master number.
By default, there are no Master Mailbox numbers assigned.
4.3 47-03-03: Master Mailbox Type on page 206.
- Assign the Master Mailbox category (
1=Call Routing, 2=Announcement, 3=Subscriber,
0=Undened).
By default, the Master Mailbox type is 3 (Subscriber).
Step 5 Set up the options for the Master Mailbox used for Department Group overow.
5.1 If you entered 1 (Call Routing) for 47-03-03: Master Mailbox Type:
- 47-04-01: Dial Action Table on page 208.
- 47-04-02: Screened Transfer Timeout on page 208.
- 47-04-03: Time Limit for Dialing Commands on page 208.
- 47-04-04: Fax Detection on page 209.
5.2 If you entered 2 (Announcement) for 47-03-03: Master Mailbox Type:
- 47-05-01: Next Call Routing Mailbox on page 210.
- 47-05-02: Repeat Count on page 210.
- 47-05-03: Hang Up After on page 210.