Program 47: IntraMail
47-01: IntraMail System Options
196 Chapter 3: Programming IntraMail for Aspire System Guide
Default
X*M#.
47-01-08: Delay in Dialing Digital Pager Callback Number
(Pager Dial Delay)
Use this option to set the delay (0-99 seconds) that occurs just before IntraMail dials the Digital Pager Call-
back Number portion of the Message Notication callout number for a digital pager. Set this delay so the
pager service has enough time to connect to the digital pager before sending the callback number. Your pager
service may be able to help you determine the best value for this option (0-99 seconds). By default, this
option is 9 seconds. When placing a digital pager notication, the system:
1. Seizes the trunk specied.
2. Dials the user-entered notication number (in MSG + OP + N).
3. Waits the 47-01-08: Delay in Dialing Digital Pager Callback Number interval.
4. Dials the number entered in 47-01-07: Digital Pager Callback Number.
The system assumes that the notication number will complete dialing approximately 4 seconds after trunk
seizure. This means that, by default, the Digital Pager Callback Number will be dialed into the pager service
about 13 seconds after trunk seizure.
See Message Notication on page 127 for more.
Options
0-99 seconds
Default
9 seconds
47-01-09: Wait Between Digital Pager Callout Attempts
(Notify Pager Intvl)
Use this option to set the minimum time (1-255 minutes) between unacknowledged or unanswered digital
pager Message Notication callouts. (A subscriber acknowledges a digital pager notication by logging onto
their mailbox.) After this interval expires, IntraMail will try the callout again (for up to the number of times
set in 47-01-14: Number of Callout Attempts). By default, this interval is 15 minutes.
If the system dials the callout number and the pager service is busy, it will retry the number in one minute.
See Message Notication on page 127 for more.
Options
1-255 minutes
Default
15 minutes
47-01-10: Wait Between Non-Pager Callout Attempts
(Notify N-Pgr Intvl)
Use this option to set the minimum time (1-255 minutes) between non-pager Message Notication callouts
in which the destination answers, says “Hello,” dials 1 to acknowledge and then enters the wrong security
code. By default, this interval is 20 minutes.
See Message Notication on page 127 for more.
Options
1-255 minutes
Default
20 minutes
47-01-11: Wait Between Busy Non-Pager Callout Attempts
(Notify Busy Intvl)
Use this option to set how long IntraMail will wait (1-255 minutes), after it dials a busy non-pager callout
destination, before retrying the callout number. The default setting for this option is 15 minutes.
See Message Notication on page 127 for more.