System Configuration 4-71
- Basic
c
d
e
(1) Specify whether or not to enable the alert mail functions by the check box. When you select
the check box, you can make mail-related settings.
(2) Select a notice level from six levels. Levels are categorized according to severity of factor
events.
(3) Allows you to send a test mail.
IMPORTANT:
Perform the mail test after you have completely configured “E-Mail Alert Settings” described in
the following pages.
Making entries in the editing window does not complete settings. You need to click [OK] after
entering all the required information to complete the BMC settings.
TIPS:
The X-Priority: field in the mail header changes according to the severity of factoring event.
Non-recoverable/Critical X-Priority: 1
Non-critical X-Priority: 3
OK/Information/Monitoring X-Priority: 5