7-6 Troubleshooting
On-screen error message Cause Action
0B83 BMC IBF or OBF
check
failed
RMC device is faulty.
Replace the CPU/IO module or ft
Remote Management Card
(option).
0B8A BMC SEL area full
There is no space to write
system event logs.
Clear system event logs after
saving them.
0B8B BMC progress check
timeout
BMC check is suspended.
Replace the CPU/IO module or ft
Remote Management Card
(option).
0B8C BMC command
access failed
BMC command access failed.
Replace the CPU/IO module or ft
Remote Management Card
(option).
0B8D Could not redirect the
console - BMC Busy
Console cannot be redirected
(BMC is busy).
There is a possibility that the
BMC was busy and could not
respond. Restart the server
again.
0B8E Could not redirect the
console - BMC Error
BMC is faulty.
Replace the CPU/IO module or ft
Remote Management Card
(option).
0B8F Could not redirect the
console – BMC
parameter Error -
Configuration is faulty.
Configure the console redirection
by using BIOS setup.
0B90 BMC Platform
Information Area
corrupted
0B91 BMC update firmware
corrupted
BMC device is faulty.
0B92 Internal Use Area of
BMC FRU corrupted
Data within SROM is faulty.
Replace the CPU/IO module or ft
Remote Management Card
(option).
0B93 BMC SDR Repository
empty
SDR data is faulty.
If updating SDR does not help,
replace the CPU/IO module or ft
Remote Management Card
(option).
0B94 IPMB signal lines do
not respond
SMC is faulty.
Replace the CPU/IO module or a
center plane after determining
where IPMB error has occurred
based on OS information.
0B95 BMC FRU device
failure
NVRAM within BMC is faulty.
0B96 BMC SDR Repository
failure
SDR repository within BMC is
faulty.
0B97 BMC SEL device
failure
SEL repository within BMC is
faulty.
0B98 BMC RAM test error BMC RAM is faulty.
Replace the CPU/IO module or ft
Remote Management Card
(option).
0B99 BMC Fatal hardware
error
BMC FPGA is faulty.
If updating FPGA does not help,
replace the CPU/IO module or ft
Remote Management Card
(option).
0B9A BMC not responding
BMC device is faulty.
Replace the CPU/IO module or ft
Remote Management Card
(option).
0B9B Private I2C bus not
responding
I2C bus is faulty.
Replace the part related to failed
I2C bus.

Table of Contents

Other manuals for NEC Express5800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Express5800 Series and is the answer not in the manual?

NEC Express5800 Series Specifications

General IconGeneral
SeriesExpress5800
CategoryServer
ProcessorIntel Xeon processors
NetworkGigabit Ethernet, 10 Gigabit Ethernet (Varies by model)
Operating System SupportWindows Server, Linux variants
Form FactorTower, Rackmount (1U, 2U, etc. - varies by model)
MemoryDDR4 ECC DIMM (Capacity varies by model)
StorageSAS/SATA HDD/SSD, NVMe SSD (Configuration varies by model)

Related product manuals