EasyManua.ls Logo

NEC PD78052 - Timer Clock Selection Register 0 Format

NEC PD78052
603 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
183
CHAPTER 8 16-BIT TIMER/EVENT COUNTER
CLOE TCL06 TCL05 TCL04 TCL03 TCL02 TCL01 TCL00
<7>6543210Symbol
TCL0
TCL03 TCL02 TCL01 TCL00
0000f
XT
(32.768 kHz)
0101f
XX
f
X
(5.0 MHz) f
X
/2 (2.5 MHz)
0110f
XX
/2 f
X
/2
(2.5 MHz) f
X
/2
2
(1.25 MHz)
0111f
XX
/2
2
f
X
/2
2
(1.25 MHz) f
X
/2
3
(625 kHz)
1000f
XX
/2
3
f
X
/2
3
(625 kHz) f
X
/2
4
(313 kHz)
1001f
XX
/2
4
f
X
/2
4
(313 kHz) f
X
/2
5
(156 kHz)
1010f
XX
/2
5
f
X
/2
5
(156 kHz) f
X
/2
6
(78.1 kHz)
1011f
XX
/2
6
f
X
/2
6
(78.1 kHz) f
X
/2
7
(39.1 kHz)
1100f
XX
/2
7
f
X
/2
7
(39.1 kHz) f
X
/2
8
(19.5 kHz)
MCS = 1
PCL Output Clock Selection
MCS = 0
FF40H 00H R/W
Address After Reset R/W
Other than above Setting prohibited
TCL06 TCL05 TCL04
0 0 0 TI00 (Valid edge specifiable)
0012f
XX
Setting prohibited f
X
(5.0 MHz)
010f
XX
f
X
(5.0 MHz) f
X
/2 (2.5 MHz)
011f
XX
/2 f
X
/2 (2.5 MHz) f
X
/2
2
(1.25 MHz)
100f
XX
/2
2
f
X
/2
2
(1.25 MHz) f
X
/2
3
(625 kHz)
1 1 1 Watch timer output (INTTM 3)
MCS = 1
16-Bit Timer Register Count Clock Selection
MCS = 0
Other than above Setting prohibited
CLOE
1 Output enabled
PCL Output Control
0 Output disabled
Figure 8-3. Timer Clock Selection Register 0 Format
Cautions 1. The TI00/INTP0 pin valid edge is set by external interrupt mode register 0 (INTM0), and
the sampling clock frequency is selected by the sampling clock selection register
(SCS).
2. When enabling PCL output, set TCL00 to TCL03, then set 1 in CLOE with a 1-bit memory
manipulation instruction.
3. To read the count value when TI00 has been specified as the TM0 count clock, the value
should be read from TM0, not from 16-bit capture/compare register 01 (CR01).
4. When rewriting TCL0 to other data, stop the timer operation beforehand.

Table of Contents