NEC PD78052 - Interval Times

NEC PD78052
603 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
248
CHAPTER 11 WATCHDOG TIMER
(2) Interval timer mode
Interrupt requests are generated at the preset time intervals.
Table 11-2. Interval Times
Interval Time MCS = 1 CS = 0
2
11
× 1/fXX 2
11
× 1/fX (410
µ
s) 2
12
× 1/fX (819
µ
s)
2
12
× 1/fXX 2
12
× 1/fX (819
µ
s) 2
13
× 1/fX (1.64 ms)
2
13
× 1/fXX 2
13
× 1/fX (1.64 ms) 2
14
× 1/fX (3.28 ms)
2
14
× 1/fXX 2
14
× 1/fX (3.28 ms) 2
15
× 1/fX (6.55 ms)
2
15
× 1/fXX 2
15
× 1/fX (6.55 ms) 2
16
× 1/fX (13.1 ms)
2
16
× 1/fXX 2
16
× 1/fX (13.1 ms) 2
17
× 1/fX (26.2 ms)
2
17
× 1/fXX 2
17
× 1/fX (26.2 ms) 2
18
× 1/fX (52.4 ms)
2
19
× 1/fXX 2
19
× 1/fX (104.9 ms) 2
20
× 1/fX (209.7 ms)
Remarks 1. f
XX : Main system clock frequency (fX or fX/2)
2. fX : Main system clock oscillation frequency
3. MCS : Oscillation mode selection register bit 0
4. Figures in parentheses apply to operation with f
X = 5.0 MHz.