398
CHAPTER 18 SERIAL INTERFACE CHANNEL 1
Figure 18-2. Timer Clock Select Register 3 Format
Caution When rewriting other data to TCL3 , stop the serial transfer operation beforehand.
Remarks 1. f
XX : Main system clock frequency (fX or fX/2)
2. fX : Main system clock oscillation frequency
3. MCS : Bit 0 of oscillation mode selection register (OSMS)
4. Figures in parentheses apply to operation with f
X = 5.0 MHz
Serial Interface Channel 1 Serial Clock Selection
TCL37 TCL36 TCL35 TCL34
0
0
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
1
1
0
0
0
1
0
1
0
1
0
1
f
XX
/2
f
XX
/2
2
f
XX
/2
3
f
XX
/2
4
f
XX
/2
5
f
XX
/2
6
f
XX
/2
7
f
XX
/2
8
MCS = 1
Setting prohibited
f
X
/2
2
(1.25 MHz)
f
X
/2
3
(625 kHz)
f
X
/2
4
(313 kHz)
f
X
/2
5
(156 kHz)
f
X
/2
6
(78.1 kHz)
f
X
/2
7
(39.1 kHz)
f
X
/2
8
(19.5 kHz)
MCS = 0
f
X
/2
2
(1.25 MHz)
f
X
/2
3
(625 kHz)
f
X
/2
4
(313 kHz)
f
X
/2
5
(156 kHz)
f
X
/2
6
(78.1 kHz)
f
X
/2
7
(39.1 kHz)
f
X
/2
8
(19.5 kHz)
f
X
/2
9
(9.8 kHz)
Other than above Setting prohibited
65432107
Symbol
TCL3 TCL37 TCL36 TCL35 TCL34 TCL33 TCL32 TCL31 TCL30
FF43H 88H R/W
Address After Reset R/W

Table of Contents