232
CHAPTER 9 8-BIT TIMER/EVENT COUNTERS 1 AND 2
(3) Square-wave output operation
Operates as square wave output with any selected frequency at intervals of the count value preset to 8-bit
compare register 10 and 20 (CR10, CR20).
The TO1/P31 or TO2/P32 pin output status is reversed at intervals of the count value preset to CR10 or CR20
by setting bit 0 (TOE1) or bit 4 (TOE2) of the 8-bit timer output control register (TOC1) to 1. This enables
a square wave with any selected frequency to be output.
Table 9-8. 8-Bit Timer/Event Counters 1 and 2 Square-Wave Output Ranges
Minimum Pulse Width Maximum Pulse Width Resolution
MCS = 1 MCS = 0 MCS = 1 MCS = 0 MCS = 1 MCS = 0
2 × 1/f
X 2
2
× 1/fX 2
9
× 1/fX 2
10
× 1/fX 2 × 1/fX 2
2
× 1/fX
(400 ns) (800 ns) (102.4
µ
s) (204.8
µ
s) (400 ns) (800 ns)
2
2
× 1/fX 2
3
× 1/fX 2
10
× 1/fX 2
11
× 1/fX 2
2
× 1/fX 2
3
× 1/fX
(800 ns) (1.6
µ
s) (204.8
µ
s) (409.6
µ
s) (800 ns) (1.6
µ
s)
2
3
× 1/fX 2
4
× 1/fX 2
11
× 1/fX 2
12
× 1/fX 2
3
× 1/fX 2
4
× 1/fX
(1.6
µ
s) (3.2
µ
s) (409.6
µ
s) (819.2
µ
s) (1.6
µ
s) (3.2
µ
s)
2
4
× 1/fX 2
5
× 1/fX 2
12
× 1/fX 2
13
× 1/fX 2
4
× 1/fX 2
5
× 1/fX
(3.2
µ
s) (6.4
µ
s) (819.2
µ
s) (1.64 ms) (3.2
µ
s) (6.4
µ
s)
2
5
× 1/fX 2
6
× 1/fX 2
13
× 1/fX 2
14
× 1/fX 2
5
× 1/fX 2
6
× 1/fX
(6.4
µ
s) (12.8
µ
s) (1.64 ms) (3.28 ms) (6.4
µ
s) (12.8
µ
s)
2
6
× 1/fX 2
7
× 1/fX 2
14
× 1/fX 2
15
× 1/fX 2
6
× 1/fX 2
7
× 1/fX
(12.8
µ
s) (25.6
µ
s) (3.28 ms) (6.55 ms) (12.8
µ
s) (25.6
µ
s)
2
7
× 1/fX 2
8
× 1/fX 2
15
× 1/fX 2
16
× 1/fX 2
7
× 1/fX 2
8
× 1/fX
(25.6
µ
s) (51.2
µ
s) (6.55 ms) (13.1 ms) (25.6
µ
s) (51.2
µ
s)
2
8
× 1/fX 2
9
× 1/fX 2
16
× 1/fX 2
17
× 1/fX 2
8
× 1/fX 2
9
× 1/fX
(51.2
µ
s) (102.4
µ
s) (13.1 ms) (26.2 ms) (51.2
µ
s) (102.4
µ
s)
2
9
× 1/fX 2
10
× 1/fX 2
17
× 1/fX 2
18
× 1/fX 2
9
× 1/fX 2
10
× 1/fX
(102.4
µ
s) (204.8
µ
s) (26.2 ms) (52.4 ms) (102.4
µ
s) (204.8
µ
s)
2
11
× 1/fX 2
12
× 1/fX 2
19
× 1/fX 2
20
× 1/fX 2
11
× 1/fX 2
12
× 1/fX
(409.6
µ
s) (819.2
µ
s) (104.9 ms) (209.7 ms) (409.6
µ
s) (819.2
µ
s)
Remarks 1. f
X : Main system clock oscillation frequency
2. MCS : Oscillation mode selection register (OSMS) bit 0
3. Values in parentheses when operated at f
X = 5.0 MHz.

Table of Contents