EasyManua.ls Logo

NEC PD78052 - A;D Converter Mode Register Format

NEC PD78052
603 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
270
CHAPTER 14 A/D CONVERTER
Figure 14-3. A/D Converter Mode Register Format
Notes 1. Set so that the A/D conversion time is 19.1
µ
s or more.
2. Setting prohibited because A/D conversion time is less than 19.1
µ
s.
Cautions 1. The following sequence is recommended for power consumption reduction of A/D
converter when the standby function is used: Clear bit 7 (CS) to 0 first to stop the
A/D conversion operation, and then execute the HALT or STOP instruction.
2. When restarting the stopped A/D conversion operation, start the A/D conversion
operation after clearing the interrupt request flag (ADIF) to 0.
Remarks 1. f
X : Main system clock oscillation frequency
2. MCS : Bit 0 of oscillation mode selection register (OSMS)
CS
<7>
TRG
<6>
FR1 FR0
4
ADM3
3210
FF80H
Address
ADM
Symbol
ADM2 ADM1 HSC
5
01H
After
Reset
R/W
R/W
ADM3
0
0
0
0
1
1
1
1
ADM2
0
0
1
1
0
0
1
1
ADM1
0
1
0
1
0
1
0
1
Analog Input Channel Selection
ANI0
ANI1
ANI2
ANI3
ANI4
ANI5
ANI6
ANI7
TRG
0
1
External Trigger Selection
No external trigger (software starts)
Conversion started by external trigger (hardware starts)
FR1
0
0
1
1
FR0
0
1
0
0
Other than above
A/D Conversion Time Selection
Note 1
f
X
= 5.0 MHz Operation
MCS = 1
80/f
X
(
Setting prohibited
Note 2
)
40/f
X
(
Setting prohibited
Note 2
)
50/f
X
(
Setting prohibited
Note 2
)
100/f
X
(20.0 s)
Setting prohibited
µ
MCS = 0
160/f
X
(32.0 s)
80/f
X
(
Setting prohibited
Note 2
)
100/f
X
(20.0 s)
200/f
X
(40.0 s)
f
X
= 4.19 MHz Operation
MCS = 1
80/f
X
(19.1 s)
40/f
X
(
Setting prohibited
Note 2
)
50/f
X
(
Setting prohibited
Note 2
)
100/f
X
(23.8 s)
MCS = 0
160/f
X
(38.1 s)
80/f
X
(19.1 s)
100/f
X
(23.8 s)
200/f
X
(47.7 s)
µ
µ
µ
µ
µ
µ
µ
CS
0
1
A/D Conversion Operation Control
Operation stop
Operation start
HSC
1
1
0
1
µ
µ

Table of Contents