9.1 Oscillation section
FRA5087
9.1 Oscillation section
●Number of output channels 1 channel
●Connector Insulated BNC connector
●Output waveform Sine wave/rectangular wave/triangular wave
●Frequency
Range 0.1 mHz to 10 MHz (In the case of rectangular or triangular wave,
be sure to use at 100 kHz or below. The waveform quality
degrades above 100 kHz.)
Setting resolution 0.1 mHz
Accuracy ±10 ppm
●AC amplitude
Range 0V to 10 Vpeak (under no load)
Setting resolution 3 digits or 0.01 mVpeak, whichever is greater
Accuracy (sine wave) Within ±0.3 dB (100 kHz or below)
Within ±1 dB (1 MHz or below)
Within ±3 dB (10 MHz or below)
(The above assumes a calibration was performed shortly prior, and
that the setting is between 100 mV to 10 Vpeak.)
Distortion (sine wave) No more than 0.2 % (when 100 kHz or below, BW 500 kHz, and
10 Vpeak output)
●DC bias
Range -10 V to 10 V (under no load)
Resolution 10 mV
Accuracy ±(1 % of DC bias setting + 2 % of AC amplitude setting + 30
mV)
(This value is applicable if a calibration was done shortly prior/)
●Output impedance 50 Ω±2 %(when 1 kHz) Unbalanced (BNC connector plug)
●Maximum output (AC+DC)
Voltage ±10 V(no load)
Current ±100 mA
●Output control
QUICK (instantly changes to the set voltage or to 0 V)
SLOW (gradually increases/decreases until reaching the set voltage or 0 V)
Phase control (The oscillation start/stop phase can be set by one degree increments.)
AC and DC can be simultaneously turned ON/OFF, while AC can be independently turned OFF.