The Computer
5-8 Manual # 42-02-1P28 A3
Building
Setup
- Controller Type, Hydraulic
- Supervisor Source (Other car, This car, M-Group)
- Number of Cars (1 Simplex, 2 Duplex)
- Car ID
- Call Config Type: Up/Down Collect, Single Collect (Simplex Only), Single Button
(Simplex Only)
NOTE: Duplex can only be Up/Down Collect
- Bottom Floor (served)
- Top Floor (served)
- Floor Eligibilities: (1-16) Opening, CFSS, Sabbath Up, Sabbath Down (Front
and Rear)
- Lobby Floor
- Egress Floor (building exit floor)
- Safety Code (Elevator Safety Code) (page 1-10)
- Flash Fire Hat (MR/HSTWY)
- Fire II with Door Closed (Yes/No) Set on fully manual doors to allow fire phase
II when the in-car firefighters’ switch is activated even when the doors are closed
or not fully open.
- Main Fire Floor
- Main Fire Side
- Alt Fire Floor
- Alt Fire Side
- Low Voltage Fire Sensor
- Flood Floor (lowest served if Flood input active)
- Landing System Type, LS-EDGE
- Primary Parking Floor (Applies to Simplex/Duplex)
- Primary Parking Door Operation (Front and Rear)
- Secondary Parking Floor (Applies to Duplex only)
- Secondary Parking Door Operation (Front and Rear)
- Car Panel Inspection: When present (Yes), HC-CTL-2-TS inputs ICEN/IN1,
ICPU/IN2, and ICPD/IN3 may only be used as Car Panel Inspection inputs
- Hoistway Access: Top, Bottom, None, or Both.
- Bottom Access Side
- Top Access Side
- EMS Floor: Set the floor number at which the EMS call to floor input is located
- EMS Side
Job Info
and Labels
- Screen Type
- Passcode. See Passcode (Restricted) on page 4-15.
- HC-MPU-2 Serial Number (Read Only)
- Job Department and Year
- Job Number
- Job Name
- Car Label
- Floor Label, per floor (1-16)
Table 5.2 Touchscreen Organization and Content