NFS-3030 Programming Manual P/N 51345:C 11/4/03 138
INDEX
NFS-3030/E
Displayless Mode
10
Two basic configurations
10
Node label
19
Node number
18
For standalone panel
18
Range
18
To view
18
Non-fire activations
Event logging
32
Non-latching
132
Note
120 seconds is the maximum delay after...(NYC
timer)
83
A module with a releasing Type ID cannot be forced
off.
70
A printout of all the messages.... (Custom Action
messages)
32
A releasing circuit with this Type Code re-
quires...(REL END BELL)
95
A setting of NO (disable) will disable keyswitch op-
eration.
19
A ULC Release circuit with this Type Code re-
quires...(REL CKT ULC)
96
ACS devices programmed for acknowledge, signal
silence...(local control=no)
19
All events except troubles are annunciated during
programming...
17
An AHJ timer does not comply with UL Standard
864.
86
An NYC timer does not comply with UL Standard
864.
83
Clearing all programs is not necessary when...(Ver-
iFire)
17
Deleting points that are active or in trouble...
53
Do not include ZF8 in the zone map of Panel Cir-
cuits used for....(releasing, zone coding)
104
If the point is not installed...(saving entries)
40
No program menus will display if a user pass-
word...(Alter status level)
17
The IZM-8RK module does not participate in Walk
Test...
45
The panel setting LCM LOCAL MODE must be set
to Yes...
37, 41
The second shot switch can only be used...(MAN
REL DELAY)
94
This soft key will not appear for modules with Type
ID...(silence option)
45
This value may not exceed 30 seconds for ULC...
22
This value must be 20 minutes for ULC...
23
To change the language of the remote display
29
When changing from an 80-column or 80-column
supervised...
27
When the ACCEPT soft key is pressed to save an
equation...
48
NYC Abort Switch
83
O
Obscuration 132
Occupancy Schedule
28, 39
Holidays
33
Output activations
Event logging
32
Output circuit
132
Overwrite (logic equation screen)
48
P
Panel Circuit 132
See Module, Panel Circuit
See Point Program
Panel circuit modules are not suitable for...
88
Panel programming, see Programming, Panel settings
Panel settings
19
AC Fail Delay
22
Alarm Verification timer
22
Auto Silence
23
Auxiliary trouble reporting
27
Custom Action message
31
Default Settings
20
Default Timers
23
Display Address
20
Event logging
32
Event Ordering
19
Holiday menu
32
Local Control
19
Local mode
20
Local Receive mode
19
Loop configuration
30
Loop programming
31
Maximum verification count
22
Panel circuit bell coding
20
PAS
23
Password
28
Piezo
19
Poll types
31
Presignal delay
23
Proprietary Supervising Station
19
Reminder Menu
20, 21
Remote Display Menu
29
Silence Inhibit
22
Supervision
27
Main power supply address
27
Printer
27
Tamper input
27
Timers
22
Trouble reminder
21
Verify-Prealarm
23
Weekly occupancy schedule
28
Panel sounder
132
Panel Timers
22
PAS (Positive Alarm Sequence)
103
Inhibit switch
103
Setting
23