281
Appendix C
DM Settings Assignment Sheets
Control Data Area
DM _____ Contents Data
DM (+0) Simple Communications Unit control
DM (+1)
Simple Communications Unit status*
1
DM (+2)
Syntax error DM address*
1
DM (+3) Communications control for Units 0 to 7
DM (+4) Communications control for Units 8 to 15
DM (+5) Communications control for Units 16 to 23
DM (+6) Communications control for Units 24 to 31
DM (+7) Unit 0 communications type
DM (+8) Starting address of Unit 0 read data area (Starting address of Unit 0 read variable type area)
DM (+9) Starting address of Unit 0 write data area (Starting address of Unit 0 write variable type area)
DM (+10) Unit 1 communications type
DM (+11) Starting address of Unit 1 read data area (Starting address of Unit 1 read variable type area)
DM (+12) Starting address of Unit 1 write data area (Starting address of Unit 1 write variable type area)
DM (+13) Unit 2 communications type
DM (+14) Starting address of Unit 2 read data area (Starting address of Unit 2 read variable type area)
DM (+15) Starting address of Unit 2 write data area (Starting address of Unit 2 write variable type area)
DM (+16) Unit 3 communications type
DM (+17) Starting address of Unit 3 read data area (Starting address of Unit 3 read variable type area)
DM (+18) Starting address of Unit 3 write data area (Starting address of Unit 3 write variable type area)
DM (+19) Unit 4 communications type
DM (+20) Starting address of Unit 4 read data area (Starting address of Unit 4 read variable type area)
DM (+21) Starting address of Unit 4 write data area (Starting address of Unit 4 write variable type area)
DM (+22) Unit 5 communications type
DM (+23) Starting address of Unit 5 read data area (Starting address of Unit 5 read variable type area)
DM (+24) Starting address of Unit 5 write data area (Starting address of Unit 5 write variable type area)
DM (+25) Unit 6 communications type
DM (+26) Starting address of Unit 6 read data area (Starting address of Unit 6 read variable type area)
DM (+27) Starting address of Unit 6 write data area (Starting address of Unit 6 write variable type area)
DM (+28) Unit 7 communications type
DM (+29) Starting address of Unit 7 read data area (Starting address of Unit 7 read variable type area)
DM (+30) Starting address of Unit 7 write data area (Starting address of Unit 7 write variable type area)
DM (+31) Unit 8 communications type
DM (+32) Starting address of Unit 8 read data area (Starting address of Unit 8 read variable type area)
DM (+33) Starting address of Unit 8 write data area (Starting address of Unit 8 write variable type area)
DM (+34) Unit 9 communications type
DM (+35) Starting address of Unit 9 read data area (Starting address of Unit 9 read variable type area)
DM (+36) Starting address of Unit 9 write data area (Starting address of Unit 9 write variable type area)
DM (+37) Unit 10 communications type
DM (+38) Starting address of Unit 10 read data area (Starting address of Unit 10 read variable type area)
DM (+39) Starting address of Unit 10 write data area (Starting address of Unit 10 write variable type area)
DM (+40) Unit 11 communications type
DM (+41) Starting address of Unit 11 read data area (Starting address of Unit 11 read variable type area)
DM (+42) Starting address of Unit 11 write data area (Starting address of Unit 11 write variable type area)
DM (+43) Unit 12 communications type
DM (+44) Starting address of Unit 12 read data area (Starting address of Unit 12 read variable type area)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CPM2C and is the answer not in the manual?

Omron CPM2C Specifications

General IconGeneral
BrandOmron
ModelCPM2C
CategoryController
LanguageEnglish

Related product manuals