n064 0140 Frequency
reference
loss detec-
tion (see
note)
Selects the frequency loss detection function for
when the frequency reference from the control
circuit terminal suddenly drops.0: Disable (Op-
erate according to frequency reference.)1: En-
able (Continue operation at 80% of frequency
reference prior to loss.)Note: Frequency refer-
ence loss: Frequency reference voltage drop of
90% within 400 ms.
Note Applicable for software version
No. 010024 or later
0,1 1 0 No 5--18
n065 0141 Multi-func-
tion analog
output type
selection
Select the multi-function analog output type.
0: Analog voltage output (functions set in n066)
1: Pulse train output (functions set in n150)
0, 1 1 0 No 5-41
n066 0142 Multi-func-
tion analog
output
Selects the monitor item with n065 set to 0.
0: Output frequency (with 10-V output at max.
frequency)
1: Output current (with 10-V output with Inverter
rated output current)
2: Main circuit DC voltage (with 10-V output at
400 [800] VDC)
3: Vector operation torque monitor (with 10-V
output at rated motor torque)
4: Output power (with 10-V output at power
equivalent to max. applicable motor capacity)
5: Output voltage (with 10-V output at
200 [200] VAC)
Note Values in ( ) apply with n067 set to 1.00.
Note Values in [ ] are for 400-V models.
0 to 5 1 0 No 5-41
n067 0143 Multi-func-
tion analog
output gain
Used to set the output characteristics of multi-
function analog output.
0.00
to
2.00
0.01 1.00 Yes 5--42
n068 0144 Multi-func-
tion analog
voltage
input gain
Set the input characteristics of multi-function
analog voltage input.
Gain:Set the frequency of maximum analog
maximum frequency as 100%.
Bias:Set the frequency of minimum analog
input (0 V) in percentage based on the
maximum frequency as 100%.
--100
to 100
1% 0 Yes 5-17
n070 0146 Multi-func-
tion analog
voltage
input filter
time con-
stant
Set a primary delay digital filter for multi-function
analog voltage input.
0.00
to
2.00
0.01 s 0.10 Yes 5-17
Note Frequency reference loss (setting value: 20) can be set for 5.5-kW and 7.5-kW Inverters only.